Jump to content

Oxford Nanopore: Difference between revisions

From Nanopore Wiki
Expand Nanopore Wiki source page with structured educational content
Expand Nanopore Wiki source page with structured educational content
 
(5 intermediate revisions by the same user not shown)
Line 2: Line 2:
<translate>
<translate>
<!--T:1-->
<!--T:1-->
[[File:Nanopore_sequencing_principle.png|thumb|right|320px|Nanopore sequencing principle. Openly licensed schematic used as a general visual guide.]]
[[File:Oxford_Nanopore_MinION_top_open.jpg|thumb|right|320px|Oxford Nanopore instruments popularized portable long-read sequencing.]]
'''Oxford Nanopore''' is part of the Nanopore Wiki learning path. Oxford Nanopore Technologies develops nanopore sequencing instruments, flow cells, chemistry, and software for real-time DNA and RNA sequencing.
'''Oxford Nanopore''' is part of the Nanopore Wiki learning path. Oxford Nanopore Technologies develops nanopore sequencing instruments, flow cells, chemistry, and software for real-time DNA and RNA sequencing.


Line 13: Line 13:


<!--T:3-->
<!--T:3-->
== Scientific basis ==
* The platform reads electrical signals produced as molecules pass through nanopores.
* Device families include portable and higher-throughput instruments.
* Interpretations should be tied to measurable quantities, experimental controls, and documented analysis settings.
* Claims should distinguish direct observations from downstream inference.
<!--T:4-->
== Typical sequencing workflow ==
== Typical sequencing workflow ==
{| class="wikitable np-knowledge-table"
{| class="wikitable np-knowledge-table"
Line 31: Line 38:
|}
|}


<!--T:4-->
<!--T:5-->
== Typical applications ==
== Typical applications ==
* Long-read genome sequencing.
* Long-read genome sequencing.
Line 38: Line 45:
* Structural variant and modification detection.
* Structural variant and modification detection.


<!--T:5-->
<!--T:6-->
== Common pitfalls ==
== Quality checks ==
* Record platform, pore or flow-cell type, chemistry, voltage or acquisition settings, and software versions.
* Use negative controls, positive controls, and replicate measurements where the claim depends on specificity.
* Report limitations such as noise, bias, sample degradation, pore instability, or model-dependent analysis.
* Do not treat vendor specifications as a substitute for application-specific validation.
 
<!--T:7-->
== Interpretation limits ==
* Comparing results without chemistry and model versions.
* Comparing results without chemistry and model versions.
* Ignoring read quality, pore count, run yield, and sample degradation.
* Ignoring read quality, pore count, run yield, and sample degradation.
* Presenting research use as clinical guidance without validation.
* A single result should not be generalized beyond the sample, protocol, instrument state, and analysis pipeline used.
* Medical, legal, regulatory, or commercial decisions require domain-specific validation beyond this educational summary.


<!--T:6-->
<!--T:8-->
== Related pages ==
== Related pages ==
* [[MinION]]
* [[MinION]]
Line 51: Line 66:
* [[Platforms]]
* [[Platforms]]


<!--T:7-->
<!--T:9-->
== References ==
== References ==
* [https://en.wikipedia.org/wiki/Oxford_Nanopore_Technologies Oxford Nanopore Technologies]
* [https://en.wikipedia.org/wiki/Oxford_Nanopore_Technologies Oxford Nanopore Technologies]

Latest revision as of 09:24, 15 July 2026

Error creating thumbnail: File with dimensions greater than 12.5 MP
Oxford Nanopore instruments popularized portable long-read sequencing.

Oxford Nanopore is part of the Nanopore Wiki learning path. Oxford Nanopore Technologies develops nanopore sequencing instruments, flow cells, chemistry, and software for real-time DNA and RNA sequencing.

Core concepts

  • The platform reads electrical signals produced as molecules pass through nanopores.
  • Device families include portable and higher-throughput instruments.
  • Output can include raw signal files, basecalled reads, alignments, and analysis reports.
  • Performance depends on chemistry, flow cell quality, library preparation, basecaller model, and analysis settings.

Scientific basis

  • The platform reads electrical signals produced as molecules pass through nanopores.
  • Device families include portable and higher-throughput instruments.
  • Interpretations should be tied to measurable quantities, experimental controls, and documented analysis settings.
  • Claims should distinguish direct observations from downstream inference.

Typical sequencing workflow

Step Description
1 Prepare DNA or RNA library according to the assay.
2 Load library onto a flow cell and start sequencing.
3 Basecall raw signal into sequence reads and quality scores.
4 Run quality control, alignment, assembly, variant calling, modification calling, or classification.

Typical applications

  • Long-read genome sequencing.
  • Metagenomics and pathogen surveillance.
  • Transcriptomics and direct RNA sequencing.
  • Structural variant and modification detection.

Quality checks

  • Record platform, pore or flow-cell type, chemistry, voltage or acquisition settings, and software versions.
  • Use negative controls, positive controls, and replicate measurements where the claim depends on specificity.
  • Report limitations such as noise, bias, sample degradation, pore instability, or model-dependent analysis.
  • Do not treat vendor specifications as a substitute for application-specific validation.

Interpretation limits

  • Comparing results without chemistry and model versions.
  • Ignoring read quality, pore count, run yield, and sample degradation.
  • A single result should not be generalized beyond the sample, protocol, instrument state, and analysis pipeline used.
  • Medical, legal, regulatory, or commercial decisions require domain-specific validation beyond this educational summary.

References