Nanopore data analysis links instruments, file formats, and computational pipelines.

Data analysis is part of the Nanopore Wiki learning path. Nanopore data analysis extracts reliable events, features, and conclusions from raw current traces or sequencing output.

Core concepts

  • For sensing, raw data are often current-versus-time traces.
  • For sequencing, data may include POD5, FAST5, FASTQ, BAM, and reports.
  • Analysis should preserve true event features while controlling noise, drift, and artifacts.
  • Quality control should be performed before and after feature extraction.

Scientific basis

  • For sensing, raw data are often current-versus-time traces.
  • For sequencing, data may include POD5, FAST5, FASTQ, BAM, and reports.
  • Interpretations should be tied to measurable quantities, experimental controls, and documented analysis settings.
  • Claims should distinguish direct observations from downstream inference.

Analysis workflow

Step Description
1 Organize metadata and raw files.
2 Assess baseline, noise, and drift.
3 Filter or detrend only with documented parameters.
4 Detect events and extract features such as blockade depth and dwell time.
5 Visualize both representative traces and population statistics.

Typical applications

  • Single-molecule sensing.
  • Sequencing quality control.
  • Method comparison and troubleshooting.

Quality checks

  • Record platform, pore or flow-cell type, chemistry, voltage or acquisition settings, and software versions.
  • Use negative controls, positive controls, and replicate measurements where the claim depends on specificity.
  • Report limitations such as noise, bias, sample degradation, pore instability, or model-dependent analysis.
  • Keep laboratory metadata linked to the raw signal or sequencing run before interpreting results.

Interpretation limits

  • Showing only attractive example traces.
  • Changing thresholds until expected results appear.
  • A single result should not be generalized beyond the sample, protocol, instrument state, and analysis pipeline used.
  • Medical, legal, regulatory, or commercial decisions require domain-specific validation beyond this educational summary.

References