Jump to content

MinION: Difference between revisions

From Nanopore Wiki
Marked this version for translation
Expand Nanopore Wiki source page with structured educational content
Line 1: Line 1:
__NOTOC__
<translate>
<translate>
= MinION = <!--T:1-->
<!--T:1-->
[[File:Nanopore_sequencing_principle.png|thumb|right|320px|Nanopore sequencing principle. Openly licensed schematic used as a general visual guide.]]
'''MinION''' is part of the Nanopore Wiki learning path. MinION is a portable nanopore sequencing device associated with Oxford Nanopore Technologies and widely used for field, teaching, and laboratory sequencing.


<!--T:2-->
<!--T:2-->
'''MinION''' is a portable nanopore sequencing device associated with Oxford Nanopore Technologies. It is often used in field sequencing, rapid pathogen surveillance, education, and small-scale sequencing workflows.
== Core concepts ==
* MinION uses disposable flow cells with many nanopore channels.
* It supports real-time sequencing and portable workflows.
* Run success depends on sample quality, library preparation, flow cell state, and software configuration.
* Downstream interpretation requires appropriate bioinformatics and quality control.


== Typical uses == <!--T:3-->
<!--T:3-->
== Practical workflow ==
{| class="wikitable np-knowledge-table"
! Step
! Description
|-
| 1
| Check flow cell status and plan library input.
|-
| 2
| Prepare and load the sequencing library.
|-
| 3
| Monitor run metrics such as active pores, yield, read length, and quality.
|-
| 4
| Analyze reads with a documented pipeline.
|}


<!--T:4-->
<!--T:4-->
* Rapid microbial or viral sequencing.
== Typical applications ==
* Field and point-of-need genomics.
* Rapid microbial and viral sequencing.
* Teaching and demonstration of nanopore sequencing.
* Teaching long-read sequencing concepts.
* Pilot experiments before scaling to larger platforms.
* Field and resource-limited deployments.
* Small genome assembly and targeted sequencing.


== Related pages == <!--T:5-->
<!--T:5-->
== Common pitfalls ==
* Assuming portability removes the need for sample quality control.
* Using old basecaller models without recording versions.
* Ignoring contamination and negative controls in field workflows.


<!--T:6-->
<!--T:6-->
== Related pages ==
* [[Oxford Nanopore]]
* [[Oxford Nanopore]]
* [[Nanopore sequencing]]
* [[Nanopore sequencing]]
* [[Bioinformatics]]
* [[Bioinformatics]]
* [[Experimental workflows]]
<!--T:7-->
== References ==
* [https://en.wikipedia.org/wiki/MinION MinION]
* [https://nanoporetech.com/ Oxford Nanopore Technologies official site]
</translate>
</translate>


<languages />
<languages />

Revision as of 10:12, 30 June 2026

Nanopore sequencing principle. Openly licensed schematic used as a general visual guide.

MinION is part of the Nanopore Wiki learning path. MinION is a portable nanopore sequencing device associated with Oxford Nanopore Technologies and widely used for field, teaching, and laboratory sequencing.

Core concepts

  • MinION uses disposable flow cells with many nanopore channels.
  • It supports real-time sequencing and portable workflows.
  • Run success depends on sample quality, library preparation, flow cell state, and software configuration.
  • Downstream interpretation requires appropriate bioinformatics and quality control.

Practical workflow

Step Description
1 Check flow cell status and plan library input.
2 Prepare and load the sequencing library.
3 Monitor run metrics such as active pores, yield, read length, and quality.
4 Analyze reads with a documented pipeline.

Typical applications

  • Rapid microbial and viral sequencing.
  • Teaching long-read sequencing concepts.
  • Field and resource-limited deployments.
  • Small genome assembly and targeted sequencing.

Common pitfalls

  • Assuming portability removes the need for sample quality control.
  • Using old basecaller models without recording versions.
  • Ignoring contamination and negative controls in field workflows.

References