MinION: Difference between revisions
Appearance
Marked this version for translation |
Expand Nanopore Wiki source page with structured educational content |
||
| Line 1: | Line 1: | ||
__NOTOC__ | |||
<translate> | <translate> | ||
<!--T:1--> | |||
[[File:Nanopore_sequencing_principle.png|thumb|right|320px|Nanopore sequencing principle. Openly licensed schematic used as a general visual guide.]] | |||
'''MinION''' is part of the Nanopore Wiki learning path. MinION is a portable nanopore sequencing device associated with Oxford Nanopore Technologies and widely used for field, teaching, and laboratory sequencing. | |||
<!--T:2--> | <!--T:2--> | ||
== Core concepts == | |||
* MinION uses disposable flow cells with many nanopore channels. | |||
* It supports real-time sequencing and portable workflows. | |||
* Run success depends on sample quality, library preparation, flow cell state, and software configuration. | |||
* Downstream interpretation requires appropriate bioinformatics and quality control. | |||
<!--T:3--> | |||
== Practical workflow == | |||
{| class="wikitable np-knowledge-table" | |||
! Step | |||
! Description | |||
|- | |||
| 1 | |||
| Check flow cell status and plan library input. | |||
|- | |||
| 2 | |||
| Prepare and load the sequencing library. | |||
|- | |||
| 3 | |||
| Monitor run metrics such as active pores, yield, read length, and quality. | |||
|- | |||
| 4 | |||
| Analyze reads with a documented pipeline. | |||
|} | |||
<!--T:4--> | <!--T:4--> | ||
* Rapid microbial | == Typical applications == | ||
* Field and | * Rapid microbial and viral sequencing. | ||
* | * Teaching long-read sequencing concepts. | ||
* Field and resource-limited deployments. | |||
* Small genome assembly and targeted sequencing. | |||
<!--T:5--> | |||
== Common pitfalls == | |||
* Assuming portability removes the need for sample quality control. | |||
* Using old basecaller models without recording versions. | |||
* Ignoring contamination and negative controls in field workflows. | |||
<!--T:6--> | <!--T:6--> | ||
== Related pages == | |||
* [[Oxford Nanopore]] | * [[Oxford Nanopore]] | ||
* [[Nanopore sequencing]] | * [[Nanopore sequencing]] | ||
* [[Bioinformatics]] | * [[Bioinformatics]] | ||
* [[Experimental workflows]] | |||
<!--T:7--> | |||
== References == | |||
* [https://en.wikipedia.org/wiki/MinION MinION] | |||
* [https://nanoporetech.com/ Oxford Nanopore Technologies official site] | |||
</translate> | </translate> | ||
<languages /> | <languages /> | ||
Revision as of 10:12, 30 June 2026

MinION is part of the Nanopore Wiki learning path. MinION is a portable nanopore sequencing device associated with Oxford Nanopore Technologies and widely used for field, teaching, and laboratory sequencing.
Core concepts
- MinION uses disposable flow cells with many nanopore channels.
- It supports real-time sequencing and portable workflows.
- Run success depends on sample quality, library preparation, flow cell state, and software configuration.
- Downstream interpretation requires appropriate bioinformatics and quality control.
Practical workflow
| Step | Description |
|---|---|
| 1 | Check flow cell status and plan library input. |
| 2 | Prepare and load the sequencing library. |
| 3 | Monitor run metrics such as active pores, yield, read length, and quality. |
| 4 | Analyze reads with a documented pipeline. |
Typical applications
- Rapid microbial and viral sequencing.
- Teaching long-read sequencing concepts.
- Field and resource-limited deployments.
- Small genome assembly and targeted sequencing.
Common pitfalls
- Assuming portability removes the need for sample quality control.
- Using old basecaller models without recording versions.
- Ignoring contamination and negative controls in field workflows.