'''Event detection''' is part of the Nanopore Wiki learning path. Event detection identifies real blockade or signal-change events in nanopore recordings and extracts comparable features from them.
'''Event detection''' is part of the Nanopore Wiki learning path. Event detection identifies real blockade or signal-change events in nanopore recordings and extracts comparable features from them.


Line 13: Line 13:


<!--T:3-->
<!--T:3-->
== Scientific basis ==
* Detection thresholds should be tied to baseline and local noise.
* Event boundaries affect dwell time, area, and shape metrics.
* Interpretations should be tied to measurable quantities, experimental controls, and documented analysis settings.
* Claims should distinguish direct observations from downstream inference.
<!--T:4-->
== Event detection workflow ==
== Event detection workflow ==
{| class="wikitable np-knowledge-table"
{| class="wikitable np-knowledge-table"
Line 34: Line 41:
|}
|}


<!--T:4-->
<!--T:5-->
== Typical applications ==
== Typical applications ==
* Quantifying blockade depth and dwell time.
* Quantifying blockade depth and dwell time.
Line 40: Line 47:
* Building training data for classification models.
* Building training data for classification models.


<!--T:5-->
<!--T:6-->
== Common pitfalls ==
== Quality checks ==
* Record platform, pore or flow-cell type, chemistry, voltage or acquisition settings, and software versions.
* Use negative controls, positive controls, and replicate measurements where the claim depends on specificity.
* Report limitations such as noise, bias, sample degradation, pore instability, or model-dependent analysis.
* Keep laboratory metadata linked to the raw signal or sequencing run before interpreting results.
 
<!--T:7-->
== Interpretation limits ==
* Using one threshold for recordings with strong drift.
* Using one threshold for recordings with strong drift.
* Failing to test false positives on blank controls.
* Failing to test false positives on blank controls.
* Treating automated output as correct without visual review.
* A single result should not be generalized beyond the sample, protocol, instrument state, and analysis pipeline used.
* Medical, legal, regulatory, or commercial decisions require domain-specific validation beyond this educational summary.


<!--T:6-->
<!--T:8-->
== Related pages ==
== Related pages ==
* [[Data analysis]]
* [[Data analysis]]
Line 53: Line 68:
* [[Troubleshooting]]
* [[Troubleshooting]]


<!--T:7-->
<!--T:9-->
== References ==
== References ==
* [https://en.wikipedia.org/wiki/Detection_theory Signal detection theory]
* [https://en.wikipedia.org/wiki/Detection_theory Signal detection theory]

Latest revision as of 09:25, 15 July 2026

Event detection identifies signal deviations from a stable baseline.

Event detection is part of the Nanopore Wiki learning path. Event detection identifies real blockade or signal-change events in nanopore recordings and extracts comparable features from them.

Core concepts

  • Detection thresholds should be tied to baseline and local noise.
  • Event boundaries affect dwell time, area, and shape metrics.
  • Weak, overlapping, or multi-level events need careful validation.
  • False positives can arise from noise, drift, bubbles, clogging, and analysis settings.

Scientific basis

  • Detection thresholds should be tied to baseline and local noise.
  • Event boundaries affect dwell time, area, and shape metrics.
  • Interpretations should be tied to measurable quantities, experimental controls, and documented analysis settings.
  • Claims should distinguish direct observations from downstream inference.

Event detection workflow

Step Description
1 Annotate experimental phases and sample addition times.
2 Estimate local baseline and noise.
3 Set candidate thresholds and minimum duration rules.
4 Merge, split, or reject events using documented criteria.
5 Export event tables and plots for review.

Typical applications

  • Quantifying blockade depth and dwell time.
  • Comparing samples or pore variants.
  • Building training data for classification models.

Quality checks

  • Record platform, pore or flow-cell type, chemistry, voltage or acquisition settings, and software versions.
  • Use negative controls, positive controls, and replicate measurements where the claim depends on specificity.
  • Report limitations such as noise, bias, sample degradation, pore instability, or model-dependent analysis.
  • Keep laboratory metadata linked to the raw signal or sequencing run before interpreting results.

Interpretation limits

  • Using one threshold for recordings with strong drift.
  • Failing to test false positives on blank controls.
  • A single result should not be generalized beyond the sample, protocol, instrument state, and analysis pipeline used.
  • Medical, legal, regulatory, or commercial decisions require domain-specific validation beyond this educational summary.